why CCE index allowed values between 0-88 only as per FAPI document?

+1 vote
565 views

Is it not possible more than 89 CCE's in any bandwidth?

posted Jun 2, 2016 by Suchakravarthi Sripathi

Share this question
Facebook Share Button Twitter Share Button LinkedIn Share Button

1 Answer

0 votes
 
Best answer

Hi sripathi,

take example 20MHZ BW FDD and CFI = MAX .i.e 3 , PHICH normal and NG = MIN i.e 1/6 . so there are 3600 R.E's in 20mhz 3 symbol PDCCH,

1 CCE = 36 R.E , so there are 3600/36 = 100 CCE, But first symbole will be occupied by reference signal , PHICH and PCFICH. in CELL ID 0.so only MAX of 87 CCE is possible out of 100 CCE . that is the reason FAPI have said only 0 - 88 is possible.

answer Jun 13, 2016 by Jaganathan
Hi jaganathan, Thanks for your explanation. As per your calculation max 87CCEs so value should be 0 to 86 . But why 0 to 88????
Hi sripathi,

I don't know, May be with other cell ID this size may vary upto 88 (My guess), because other cell ID will have different reference signal and PHICH and PCFICH.
ok thank you jaganathan ...
Similar Questions
+1 vote

Am not able to find out in 36.413,Please provide reference?

+2 votes

I had gone through the CCE index start computation for the eNODeb , which i am unable to understand it properly, can any one provide detailed view on it, will it get any difference in case if you have multi users.

...