Is it mandatory to read PCFICH in every SF?

+1 vote
365 views
Is it mandatory to read PCFICH in every SF?
posted Jul 26, 2017 by Bharat Kumar

Share this question
Facebook Share Button Twitter Share Button LinkedIn Share Button

1 Answer

0 votes

Hi bharat,

yes it is mandatory to read PCFICH in every SF, because UE will not have any idea about PDCCH symbols. So when it reads PCFICH it comes to know PDCCH symbols and reads it accordingly.

answer Jul 27, 2017 by Jaganathan
But why it is needed every SF, one time if UE reads then it can store that information right?
PDCCH symbol is not fixed it will be varying  every SF. If suppose in some SF no UE's to schedule then PDCCH symbols will be less, if more UE's top schedule then PDCCH symbols will be more based on these ENB will change PDCCH symbols.
Similar Questions
+1 vote

Is it mandatory that same LC group should be transmitted? For e.g ENB gives grant for one LCG BSR but i want to send data on other LCG with the same grant is it possible?

+3 votes

When UE is asking for DL dedicated bearers (e.g QCI 6) , Is it mandatory that Enb has to configure the UL dedicated bearers with QCI 6 or it UL bearer is optional. If it is mandatory then if UE dont have any uplink transmission means that resource is waste.How to handle this scenario

0 votes

DL data will be decoded by number of UE's under a eNB ,but how a particular UE will know the dl data coming is to that UEonly at PHY level because the CRNTI will be at MAC header

...