top button
Flag Notify
    Connect to us
      Site Registration

Site Registration

How UE will be connected to Network after power saving mode

0 votes
518 views

UE goes in power saving mode after expiry of timer t3324 then ue is not reachable from network but UE is registered in the the network . What is the procedure to contact with network ? If timer t3324 is 1hr , UE does not listen paging in 1hr interval then how ue will start using data ?

posted Oct 5, 2017 by Rakesh Kumar Suman

Share this question
Facebook Share Button Twitter Share Button LinkedIn Share Button

1 Answer

+2 votes

Hi Rakesh, I don't have depth knowledge in Power Saving Mode (PSM) but would like to share my learning so far in this area.
When UE moves from connected to idle mode, it stars T3324 and UE remains reachable through paging from network side but after expiry of T3324, UE goes into power saving mode. In power saving mode, however UE can't be reach through paging but UE can initiate data transmission since UE is already registered with network.

answer Oct 9, 2017 by Harshita
Similar Questions
0 votes

what is difference between power saving mode and eDRX ?

+1 vote

Could you please send any one call flow/concept of eDRX and power saving mode from mme /epc perspective?

+1 vote

After attach procedure shut down enodeb only and again run enodeb then how it will get connect to ue(through which message enb will get ue context).

+1 vote

Suppose MME is getting CS call notification for MSC then How MME will notify to UE when
1. UE is idle mode. ?
2. UE is in connected mode?

...