Does UE sends measurement reports periodically or only event occurs?

+3 votes
483 views

If ENB configures some measurement event say A1,A2,A3 etc, take e.g A2 event threshhold as -100Dbm, and serving cell thrs crosses -100 then UE will send A2, after this event UE is still facing signal strength as -100dB over a long period, will UE sends second time A2 event or only once?

posted Jun 21, 2018 by Jaganathan

Share this question
Facebook Share Button Twitter Share Button LinkedIn Share Button

1 Answer

+1 vote

Hi, event A2 triggered at:
MEAsserv + Hyst < Threshold
If serving cell becomes worse than a threshold (example= -100dbm) it generates A2 . After generating the A2, I think UE will not report A2 frequently .
As Hyst value is configured, it reduces the number of Measurement Report messages sent to the eNB for small fluctuation.
Hysterisis will prevent unnecessarily frequent measurement report caused by small range of fluctuation.
If the fluctuation is higher ( serving cell /neighbor cell), it will take decision based on that.
Also, report can be event-triggered or periodical. An event-based measurement report will be transmitted when the criteria meet.
Periodical measurement reports are sent based on the reporting configuration. Its operator specific.

answer Jun 25, 2018 by Mohit Mohan
Similar Questions
+1 vote

Does UE reports neighbor cells in order of RSRP in measurement report of A3 event ?

+4 votes

I have gone through the measurement config/ report messages.I found that in meas report UE can send PCI, RSRP, RSRQ, CGI report at a time.

Will UE will send CGI report also at the same time or UE will send only when ENB request UE for the ECGI with the Report ECGI by giving pci ?

...