When enodeb about to start sending measconfig inside rrc connection reconfiguration to get measurement reports from UE?

+3 votes
741 views

We know before taking decision for handover in LTE system measurement reports are taken into account for an UE. UE has to send measurement report to enodeb but how enodeb realize that now I has to configure to UE to send measure report . To perform these measurements Ue uses concept of measurement gap and then get the information from other cell/technology/frequency. During this measurement activity UE doesn't schedule any UL/DL data and measurement procedure is also a battery consuming activity. my question is that how eNodeb trade off between measurement and UL/DL data.

posted Jul 3, 2013 by Vimal Kumar Mishra

Share this question
Facebook Share Button Twitter Share Button LinkedIn Share Button

1 Answer

0 votes

Measurement gap has high priority than data transmission/reception. If network keep sending data or UL grant during the DRX cycle, UE can never gets into OFF period meaning it cannot have time to switch to target cell for CGI detection.
You can check the following links
http://www.sharetechnote.com/html/Handover_LTE.html
http://www.sharetechnote.com/html/Handbook_LTE_DRX.html

answer Jul 4, 2013 by Salil Agrawal
Similar Questions
+4 votes

There are couple of procedures are defined which consist of NAS as well as RRC signalling messages exchange.
Some of the NAS message sends to an UE through RRC Connection Reconfiguration message as piggybacked and some as DL Info transfer.

I want to know, Is there any procedure exists in lte when an UE receives RRC Connection Reconfiguration along with NAS message and responds back to network with NAS message first and then Reconfiguration Complete to eNodeB.

Usually, I saw UE sends RRC Connection Reconfiguration Complete message first then NAS response message.

+4 votes

Since Ue can be configured for measure at the time of RRC Connection Setup. What is the probability to get mobility control info inside RRC Connection Reconfiguration as part of initial attach procedure.

+3 votes

How to inform MME about UE movement from Source eNB to Target eNB after UE sending Re-establishment with HO failure to target eNB during handover. In this case HO notify or path switch is applicable ?

...