when periodicPHR-Timer, prohibitPHR-Timer will get start and expire? What is dl-PathlossChange?

+2 votes
6,191 views
when periodicPHR-Timer, prohibitPHR-Timer will get start and expire? What is dl-PathlossChange?
posted Oct 5, 2016 by Sneha Maganahalli

Share this question
Facebook Share Button Twitter Share Button LinkedIn Share Button

2 Answers

0 votes
 
Best answer

HI,

Based on Reference Signals strength UE calculates the pathloss. dl-PathlossChange is the threshold parameter, upto this value pathloss can be acceptable. If pathloss value changes beyond this value UE sends PHR to the network.

periodicPHR-Timer is configurable parameter as per vendor. lets suppose SF100 configured, UE have to send PHR once in every 100 subframes.

prohibitPHR-Timer is also configurable parameter, which denotes when this timer running UE should not send PHR.

answer Oct 5, 2016 by Suchakravarthi Sripathi
Based on which reference signal path-loss is calculated? Is PHR is sent on Transport-Block? If so, in which slot or subframe it is sent?
PHR is sent through ULSCH channel , whenever UE has UL grant it will send as part of UL TB.
based power notified by network and the measured RS power at UE antenna port UE will calculate pathloss.
PHR is the mac control element ... obviously its part of MAC PDU . All control elements resides first in the formation of the TB.

Am not sure which RS uses for path-loss .. will update you soon
0 votes

Hi,

Whenever UE gets UL grant , then UE will start or restart the PHRperiodic timer and Prohibit TImer.

Dlpathloss change is a thrshhold value ,If current pathloss is greater than the dlpathlosschange then UE will trigger a PHR report.

answer Oct 5, 2016 by Jaganathan
please explain more on it. I thought that it will start when the UE will send the TB with PHR in it.
When UE recieve first UL grant after PHR configuration,then UE will start the timer.

Then whenever it expires it will trigger PHR and restart the timer.
When the timer expires you will send PHR in case of both PHRperiodic and PHRprohibit. It means untill the timer expires you are not going to send the PHR.
PHRprohibit is defined as:Timer which the UE should maintain between sending 2 consecutive PHRs. Therefore why you need PHRprohibit timer when PHRperiodic alone can do the PHRprohibit timer job.
Similar Questions
+1 vote

After expiry is it mandatory to send BSR in next SF or can it be delayed for some reason ?

+1 vote

How 8CA in DL and 4CA in UL work? How much throuhow 8CA in DL and 4CA in UL work? how much throughput will get? Which ue support this much throughput? Which LTE specs support this feature? Which ue support this much throughput?

...