Reestablishment triggers after Source cell is detected as Radio ink failure, If UE is not able to detect any other cell during this time how long it can wait to find new cell to trigger Reestablishment .
Hi Jagan, Timer T311 starts at the initiation of RRC connection reestablishment procedure. It stops upon selection of suitable E-UTRA cell OR a cell using another RAT. default value ms1000-LTE default value ms30000 - 5G
after timer expiry UE goes in RRC_Idle state .
If HO fails the UE will initiate contention based reestablishment and connect to some ENB, But target ENB have provided the contention free Rach preamble , at failure case how long ENB will hold this preamble because it has to release for other UE?
NR eNB will not send an ACK/NACK . So UE should hold the buffer untill it receives same HARQ process DCI0. How long it hold if eNB delays the Scheduling same HARQ process?
UE Active time includes after SR transmission as per UE spec. How long it stays in active time after SR transmission?