top button
Flag Notify
    Connect to us
      Site Registration

Site Registration

eNB include only utra objects or eutra objects or both while configuring UE to send Measurement reports during IRAT ho?

+3 votes
656 views
eNB include only utra objects or eutra objects or both while configuring UE to send Measurement reports during IRAT ho?
posted Oct 21, 2015 by Gnanendra Reddy

Share this question
Facebook Share Button Twitter Share Button LinkedIn Share Button

3 Answers

+2 votes

Only UTRA objects will be configured since its IRAT HO

Can include GERAN objects as well if IRAT HO to GERAN

answer Oct 22, 2015 by Alkesh Mehta
0 votes

Unless eNodeB deletes the previously configured measurement ids , it will be present at UE side and UE sends measurement report to eNodeB once it a particular event hits.

Please correct me if I misunderstood the concept.

answer Oct 22, 2015 by Harshita
0 votes

Yes UE will have mesurement ids sent during initial attach. Based on the measurements sent by UE, eNB will reconfigure UE to send reports depending on the type of measurements UE sends.

answer Oct 22, 2015 by Alkesh Mehta
Similar Questions
+2 votes

ENB will include only UTRA objects or both EUTRA and UTRA objects in meas config for UE to send measurement reports during IRAT HO ???

+3 votes

Suppose UE have mobility parameters for intra LTE HO . UE try to sync with target eNB to confirm HO completion. So UE performs rach with target eNB. Suppose rach is not getting successful then how many time UE will perform rach at target eNB .

+3 votes

If ENB configures some measurement event say A1,A2,A3 etc, take e.g A2 event threshhold as -100Dbm, and serving cell thrs crosses -100 then UE will send A2, after this event UE is still facing signal strength as -100dB over a long period, will UE sends second time A2 event or only once?

...